Guest

Preview Tool

Cisco Bug: CSCvv87524 - lanes information is wrong for 4 lane pluggable after swapping of SRBD or FR

Last Modified

Oct 19, 2020

Products (2)

  • Cisco Network Convergence System 1000 Series
  • Cisco IOS XR Software

Known Affected Releases

7.3.1.BASE

Description (partial)

Release-note

Symptom:
When a QSFP28 optics which has less than 4 lanes is replaced with a four lane optics, post replacement we see power only for less number of lanes reported.

For example, swapping a SR-BIDI pluggable (which has only 2 lanes) with LR4 which should have 4 lanes, results in the following reading:

Total TX Power = 5.98 dBm
Total RX Power = 4.50 dBm

Lane Laser Bias TX Power RX Power Output Frequency
---- ---------- ---------- ---------- ----------------
1 76.3 % 2.95 dBm 1.29 dBm 231.39 THz
2 75.7 % 2.99 dBm 1.69 dBm 230.59 THz
3 0.0 % -40.00 dBm -40.00 dBm 229.79 THz    <<<<
4 0.0 % -40.00 dBm -40.00 dBm 230.25 THz    <<<<

Conditions:
when customer replace a port having FR or SR BiDi with any 4 lane QSFP28 pluggable