Guest

Preview Tool

Cisco Bug: CSCvv69160 - P0V9_SAS UC & UNC threshold need to be adjusted for B260/460 using V2 CPUs

Last Modified

Oct 28, 2020

Products (1)

  • Cisco Unified Computing System

Known Affected Releases

4.1(1a)B

Description (partial)

Symptom:
UCS firmware: 4.1(1b)B
UCS B260 and B460 using V2 CPUs (UCSB-EX-M4-1)

Error seen:

Code: F1237
Last Transition Time: 2020-09-10T05:42:46.191
ID: 15621308
Status: None
Description: sys/chassis-3/blade-1/health-led shows error. Reason: P0V9_SAS:Voltage Threshold Crossed;
Affected Object: sys/chassis-3/blade-1/health-led
Name: Equipment Health Led Minor Error
Cause: Health Led Amber
Type: Equipment
Acknowledged: No
Occurrences: 74 
Creation Time: 2020-07-14T22:26:11.540
Original Severity: Minor
Previous Severity: Minor
Highest Severity: Minor

This same error was fixed for UCSB-EX-M4-2 and UCSB-EX-M4-3 under bug CSCuy05744. 
this bug is specific for UCSB-EX-M4-1

Conditions:
Sensor Name      | Reading | Unit         | Status | LNR     | LC      | LNC     | UNC     | UC      | UNR     |
=================|=========|==============|========|=========|=========|=========|=========|=========|=========|
P0V9_SAS         | 0.975   | Volts        | OK     | 0.850   | 0.881   | na      | na      | 0.983   | 1.014   | 

- 09/09/2020 05:18:14 EDT | CIMC | Voltage P0V9_SAS #0x11 | Upper critical - going high | Asserted | Reading 0.98 >= Threshold 0.98 Volts
- 09/09/2020 05:18:16 EDT | CIMC | Platform alert LED_BLADE_STATUS #0xf2 | LED color is amber | Asserted
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.