Guest

Preview Tool

Cisco Bug: CSCvv40316 - FDM - Unable to add the BGP 11th neighbor using smart CLI routing object

Last Modified

Aug 31, 2020

Products (1)

  • Cisco Firepower NGFW

Known Affected Releases

6.4.0.9 6.5.0 6.6.0 6.7.0

Description (partial)

Symptom:
Error saving BGP Smart CLI object: "This command cannot be repeated but it appears more than once in the configuration. Please remove the repeated commands"

Conditions:
Reproduced the same, exact issue on virtual FTD 6.4.0.9

1) Went to FDM > Advanced Configuration > Smart CLI > Routing > BGP Object
2) Added 10 neighbors from 10.198.174.21 to 10.198.174.30, with the following configuration
  neighbor 10.198.174.21 activate
  neighbor 10.198.174.21 next-hop-self
  neighbor 10.198.174.21 prefix-list in_2peer in
  neighbor 10.198.174.21 prefix-list out-peer out
3) When 10.198.174.31 is added, and then click OK to save, it gives an error: "This command cannot be repeated but it appears more than once in the configuration. Please remove the repeated commands"