Guest

Preview Tool

Cisco Bug: CSCvv33621 - vftd: diskmanager monitoring doesnt work correctly on upgrade

Last Modified

Sep 02, 2020

Products (1)

  • Sourcefire Defense Center

Known Affected Releases

6.6.1

Description (partial)

The Virtual FTD distributions upgraded to the 6.6.1 software release may experience disk usage alerts some time after the upgrade because temporary run-time files are not removed from the /ngfw/var/sf directory after the 6.6.1 upgrade event until either the system is restarted or the disk usage manager process is restarted..

Symptom:
The Virtual FTD device may experience a disk usage warning after upgrading to the 6.6.1 software.

Conditions:
The conditions when this might occur is after an existing Virtual FTD unit is upgraded to the 6.6.1 release and the device is not restarted at all.  Due to a patch installation timing issue the disk usage manager process does not pick up the the /ngfw/var/sf directory to monitor and manage on the first try and files under this directory can grow unbounded until either the disk usage manager process is restarted.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.