Guest

Preview Tool

Cisco Bug: CSCvu82199 - Unable to configure OMP hold timer higher than 900 seconds.

Last Modified

Jul 08, 2020

Products (1)

  • Cisco vEdge Router

Known Affected Releases

19.2.2

Description (partial)

Symptom:
Unable to configure OMP hold timer higher than 900 seconds.

Conditions:
Configured OMP hold timer as 1000 , 1500, 2000 seconds. Looks like OMP timer is capped at 900 Seconds. 

Because of this behavior we are unable to toggle Hello-tolerance and hello-interval. Refer attached test results

BR1-vedge5k# sh run omp | details
omp
 no shutdown
 send-path-limit  4
 ecmp-limit       4
 graceful-restart
 timers
  holdtime               1000
  advertisement-interval 1
  graceful-restart-timer 43200
  eor-timer              300
 exit
 advertise connected
 advertise static
!
BR1-vedge5k# sh omp det
                      ^
% Invalid input detected at '^' marker.
BR1-vedge5k# show omp peers detail | i hold
hold-time                 900
BR1-vedge5k#
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.