Cisco Bug: CSCvu14998 - N9K-C93180YC-EX// Power supply reported as "shutdown" but still operational

Last Modified

Sep 30, 2020

Products (1)

  • Cisco Nexus 9000 Series Switches

Known Affected Releases

7.0(3)I7(7.50) 9.3(3)III9(0.33)

Description (partial)

Symptom:
Power supplies (including, but not limited to: NXA-PAC-650W-PE or NXA-PAC-650W-PI) could be seen reported as shutdown on N9K-C93180YC-EX device as per "show environment power detail" command. At the same time the device continues to operate normally even with all the inserted power supplies reported as shutdown. During the issue "OK" LED is seen to be either green or flashing green, and "Fault" LED is seen to be off

Conditions:
Seen in versions 7.0.3.I7.7 and 9.3.3 as well