Guest

Preview Tool

Cisco Bug: CSCvu10904 - cEdge App Data No Longer Available in vManage When Cflowd Traffic is Sent to More than One Analyzer.

Last Modified

May 14, 2020

Products (1)

  • Cisco XE SD-WAN Routers

Known Affected Releases

16.12.2r 19.2.1

Description (partial)

Symptom:
cEdge application data no longer available in vManage GUI within Network --> Monitor. vEdges are not affected.

Conditions:
Within the user's policy they configured Cflowd data to be sent to their internal network analyzer.

  !
 cflowd-template cflow_cEdge_4351
  flow-active-timeout 30
  flow-inactive-timeout 60
  flow-sampling-interval 30
  template-refresh 90
  collector vpn 0 address <IP Address> port 9996 transport transport_udp source-interface GigabitEthernet0/0/2
 !



 !
 cflowd-template cflow_cEdge_4331
  flow-active-timeout 30
  flow-inactive-timeout 60
  flow-sampling-interval 30
  template-refresh 90
  collector vpn 0 address <IP Address> port 9996 transport transport_udp source-interface GigabitEthernet0/1/0
 !
 cflowd-template cflow_vEdge_2000
  flow-active-timeout 30
  flow-inactive-timeout 60
  flow-sampling-interval 30
  template-refresh 90
  collector vpn 0 address <IP Address> port 9996 transport transport_udp source-interface ge2/0
 !
 cflowd-template cflow_vEdge_1000
  flow-active-timeout 30
  flow-inactive-timeout 60
  flow-sampling-interval 30
  template-refresh 90
  collector vpn 0 address <IP Address> port 9996 transport transport_udp source-interface ge0/0
 !
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.