Symptom:
DAD links on a stackwise virtual pair are put into err-disable due to "spanning-tree portfast bpduguard" default configuration.

Conditions:
Following global configurations (or equivalent) are present:

spanning-tree portfast bpduguard default
spanning-tree portfast default

This can happen upon reload of any member of a stackwise virtual setup.

This is a day 1 issue which can potentially affect any Cat9K platform running stackwise virtual setup.