Description (partial)

Symptom:
On ASA failover pair, the status of an interface might shows the incorrect status

1. mgmt interface is shut down in the active unit
2. Show failover from the active unit it shows the correct status (normal behavior)

 This host: Primary - Active 
                Active time: 15330 (sec)
                slot 1: ASA5516 hw/sw rev (3.0/9.8(4)10) status (Up Sys)
                  admin Interface management (172.21.37.6): Link Down (Not-Monitored)
3. On Secondary unit, show failover output shows its own mgmt interface as down (abnormal behavior)

        This host: Secondary - Standby Ready 
                Active time: 173 (sec)
                slot 1: ASA5516 hw/sw rev (3.0/9.8(4)10) status (Up Sys)
                  admin Interface management (172.21.37.7): Link Down (Not-Monitored)
        Other host: Primary - Active 
                Active time: 15385 (sec)
                slot 1: ASA5516 hw/sw rev (3.0/9.8(4)10) status (Up Sys)
                  admin Interface management (172.21.37.6): Normal (Not-Monitored)

Conditions:
This issue is seen only on the interface which has the monitor-interface feature disabled
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.