Cisco Bug: CSCvs62823 - Wrong CPS error message during OCHNC circuit failure with unsupported LMP configuration

Last Modified

Jan 16, 2020

Products (1)

  • Cisco ONS 15454 Series Multiservice Provisioning Platforms

Known Affected Releases

11.00

Description (partial)

Symptom:
The error "CPS-1152: Head termination point(s) are not valid for DWDM" is shown when creating a WSON circuit.

Conditions:
LMP is configured with a not supported FEC and/or trunkMode