Guest

Preview Tool

Cisco Bug: CSCvi62014 - PWR-6KW-AC-V3 detecting false alarm

Last Modified

Aug 16, 2018

Products (9)

  • Cisco ASR 9000 Series Aggregation Services Routers
  • Cisco ASR 9910 Router
  • Cisco IOS XR Software
  • Cisco ASR 9922 Router
  • Cisco ASR 9010 Router
  • Cisco ASR 9904 Router
  • Cisco ASR 9006 Router
  • Cisco ASR 9001 Router
  • Cisco ASR 9912 Router

Known Affected Releases

6.2.3.BASE

Description (partial)

Symptom:
PWR-6KW-AC-V3 detectiog false alarm. it polls the status per 5 second.

If it detecting following alarm and clear 5 seconds later. it is no harm and this is cosmetic


envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_OUTPUT_STAGE_OT) :DECLARE :0/PT2-PM1: Power tray 2 power module 1 is under HW_OUTPUT_STAGE_OT condition.
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_INPUT_STAGE_OT) :DECLARE :0/PT2-PM1: Power tray 2 power module 1 is under HW_INPUT_STAGE_OT condition.
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_VIN_VOLT_OOR) :DECLARE :0/PT2-PM1: Power tray 2 power module 1 is under HW_VIN_OUT_OF_RANGE condition.
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_NO_INPUT_DETECTED) :DECLARE :0/PT2-PM1: Power tray 2 power module 1 is under HW_NO_INPUT_DETECTED condition.
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_VIN_A_VOLT_OOR) :DECLARE :0/PT2-PM1: Power tray 2 power module 1 is under HW_VIN_A_OUT_OF_RANGE condition(input A < 84V or > 269V).
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_VIN_B_VOLT_OOR) :DECLARE :0/PT2-PM1: Power tray 2 power module 1 is under HW_VIN_B_OUT_OF_RANGE condition(input B < 84V or > 269V).
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_NO_INPUT_A_DETECTED) :DECLARE :0/PT2-PM1: Power tray 2 power module 1 is under HW_NO_INPUT_A_DETECTED_AC condition.
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_NO_INPUT_B_DETECTED) :DECLARE :0/PT2-PM1: Power tray 2 power module 1 is under HW_NO_INPUT_B_DETECTED_AC condition.


envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_OUTPUT_STAGE_OT) :CLEAR :0/PT2-PM1: Power tray 2 power module 1 condition HW_OUTPUT_STAGE_OT is cleared.
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_INPUT_STAGE_OT) :CLEAR :0/PT2-PM1: Power tray 2 power module 1 condition HW_INPUT_STAGE_OT is cleared.
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_VIN_VOLT_OOR) :CLEAR :0/PT2-PM1: Power tray 2 power module 1 condition HW_VIN_OUT_OF_RANGE is cleared.
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_NO_INPUT_DETECTED) :CLEAR :0/PT2-PM1: Power tray 2 power module 1 condition HW_NO_INPUT_DETECTED is cleared.
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_VIN_A_VOLT_OOR) :CLEAR :0/PT2-PM1: Power tray 2 power module 1 condition HW_VIN_A_OUT_OF_RANGE is cleared.
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_VIN_B_VOLT_OOR) :CLEAR :0/PT2-PM1: Power tray 2 power module 1 condition HW_VIN_B_OUT_OF_RANGE is cleared.
envmon[3969]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :Power Module Error (PM_NO_INPUT_A_DETECTED) :CLEAR :0/PT2-PM1: Power tray 2 power module 1 condition HW_NO_INPUT_A_DETECTED_AC is cleared.

Conditions:
no
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.