Description (partial)

Symptom:
On Nexus 5500/5600 switches, fwm crash may be observed upon FIB TCAM exhaustion with continuous route updates.

Conditions:
When the FIB is exhausted and we send continuous route updates and Join/leaves for the existing mroutes this crash was observed. Note that the exhaustion was created in a local setup with this value "hrt-32-stm-224" as route resource template