Symptom:
in show environment power , you will see negative value of "Total Power Available for additional modules"  

snip
snip

Power Usage Summary:
--------------------
Power Supply redundancy mode (configured)                PS-Redundant
Power Supply redundancy mode (operational)               PS-Redundant
 
Total Power Capacity (based on configured mode)            9000.00 W
Total Grid-A (first half of PS slots) Power Capacity       12000.00 W
Total Grid-B (second half of PS slots) Power Capacity         0.00 W
Total Power of all Inputs (cumulative)                     12000.00 W
Total Power Output (actual draw)                           4469.00 W
Total Power Input (actual draw)                            4747.00 W
Total Power Allocated (budget)                             13140.00 W
Total Power Available for additional modules               -4140.00 W >>>

Conditions:
I7(3) code
and  { having 4 PSUs (N9K-PAC-3000W-B) OR four or more FMs (N9K-C9508-FM-E) }

This only affects chassis which has N9K-C9508-FM-E and not any other fabric module.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.