Symptom:
When an ISL diagnostic test runs for its duration it does not automatically output the stop statistics. An explicit stop command must be issued to see the statistics
<pre>
MDS9710# show clock ; diagnostic isl generator interface fc9/1 start duration 10
Time source is NTP
17:14:54.204 EST Wed Jan 24 2018
Waiting for sync to be achieved on the link ....
Link initialized successfully. Starting the test.
MDS9710#
</pre>

More than 10 seconds has elapsed so the test should be stopped but it still displays:
 
<pre>
MDS9710# show clock ; show diagnostic isl status index start 0 num 200
Time source is NTP
17:15:08.514 EST Wed Jan 24 2018
Status of isl_daig tests in progress:
----------------------------------------------------------
Index  Interface        Mode <Gen/Ref>          Test
----------------------------------------------------------

 0      fc9/1           Generator        SH Traffic Test
----------------------------------------------------------
 </pre>

The stop command must be issued to get any statistics:

<pre>
MDS9710# show clock ; diagnostic isl generator interface fc9/1 stop
Time source is NTP
17:15:30.814 EST Wed Jan 24 2018

---------------------------------------------------------
Traffic test Result for port:                    fc9/1
Packets Transmitted:                             30676524
Packets Recieved:                                30676524
ISL traffic Efficiency (percent):                100.0000
---------------------------------------------------------
</pre>

Conditions:
All using the ISL diagnostic generator test
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.