Guest

Preview Tool

Cisco Bug: CSCuw20002 - N7k - Temperature sensors stalls for linecards after EPLD update

Last Modified

Apr 06, 2018

Products (8)

  • Cisco Nexus 7000 Series Switches
  • Cisco Nexus 7000 10-Slot Switch
  • Cisco Nexus 7000 4-Slot Switch
  • Cisco Nexus 7700 6-Slot Switch
  • Cisco Nexus 7700 18-Slot Switch
  • Cisco Nexus 7000 18-Slot Switch
  • Cisco Nexus 7700 10-Slot Switch
  • Cisco Nexus 7000 9-Slot Switch

Known Affected Releases

6.2(12)

Description (partial)

Symptom:
On N7k(N77-SUP2E), Temperature sensors may stalls or stops responding for linecards after EPLD update to 6.2.12 nx-os image. It seems like platform timer which runs every minute to poll the temperature is not running. Tried Manually reading the sensors..and it read the correct values. As these timers are managed by the epld code. Suspecting if EPLD upgrade trigged the event.

In customer setup we have seen some instance where for linecards polling never started after upgrade and in some instances it started the polling after the upgrade but stalls as soon as module hit the high temperature threshold.

Conditions:
NX-OS and EPLD(system auto-upgrade epld) update to 6.2.12
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.