Description (partial)

Symptom:
Line protocol on Serial DS3 interface configured for frame-relay on SM-X-1T3/E3 card goes down due to received punt packets not incrementing.
The interface however keeps sending frame-relay LMI's but since it is not able to punt received packets, the interface does not show any LMI's being received.

In the debugs we see MYSEEN counter incrementing but YOURSEEN counters does not increment.

Serial1/0/0(out): StEnq, myseq 2, yourseen 0, DTE down
datagramstart = 0x7FD45F5F0B5C, datagramsize = 13
FR encap = 0xFCF10309
00 75 01 01 00 03 02 02 00 
 

Serial1/0/0(out): StEnq, myseq 3, yourseen 0, DTE down
datagramstart = 0x7FD45F61949C, datagramsize = 13
FR encap = 0xFCF10309
00 75 01 01 00 03 02 03 00 

=============================================================

In "sh plat hard qfp act infra punt statistics interface <QFP handle >" output, we see the Received Punt Packet DO NOT increment:

<snip>
Per Interface Punt-Inject statistics

  received punt packets      393231
</snip>

Conditions:
Issue is seen when Serial interface is configured for Frame-relay as the Layer 2 protocol.

QoS configured with Voice , video & data traffic
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.