15.2(1)SY

Description (partial)

Symptom:
Standby processor removed or reloaded due to MCL error.

*Jun  1 20:33:05.727: %ISSU-SW1-3-INCOMPATIBLE_PEER_UID: Setting image (c6848x-ADVENTERPRISEK9-M), version (15.2(1.2.31)SY1) on peer uid (513) as incompatible
*Jun  1 20:33:05.727: SW1: Config Sync: Bulk-sync failure due to Servicing Incompatibility. Please check full list of mismatched commands via:
  show redundancy config-sync failures mcl

*Jun  1 20:33:05.727: SW1: Config Sync: Starting lines from MCL file:
interface mgmt0
 ! <submode> "interface"
- speed 1000
 ! </submode> "interface"

*Jun  1 20:33:07.675: %PFREDUN-SW1-6-ACTIVE: Standby processor removed or reloaded, changing to Simplex mode

Conditions:
VSS formed between  Primus and transformer as standby. Problem seen on boot-up time.