Symptom:
UE Initiated PDN Disconnections- Attempted and Success counter is not getting populated for the scenario, given below:
1. Initiate an EPS attach.
2. Initiate additional PDN connection procedure.
3. Initiate a PDN Disconnect procedure for the second PDN.
4. Do not send the 'DEACTIVATE_EPS_BEARER_CONTEXT_ACCEPT' message upon receiving the 'DEACTIVATE_EPS_BEARER_CONTEXT_REQUEST' message.

Conditions:
If the message 'DEACTIVATE_EPS_BEARER_CONTEXT_ACCEPT' is not sent upon receiving the 'DEACTIVATE_EPS_BEARER_CONTEXT_REQUEST' message, then the following issues are observed:

a)UE Initiated PDN Disconnections- Attempted and Success counters are not pegged even after retries. Attempted and Success counters should peg to 1 as PDN Disconnect procedure is considered successful even if the accept message from UE is not received.

Note: Counters get populated properly if MME receives the 'DEACTIVATE_EPS_BEARER_CONTEXT_ACCEPT' message. 

b)The re-transmission happens only 3 times instead of 4, which is supposed to be the default.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.