Guest

Preview Tool

Cisco Bug: CSCus79378 - VLANs suspend when vPC config removed from shutdown peerswitch interface

Last Modified

Feb 03, 2017

Products (9)

  • Cisco Nexus 6000 Series Switches
  • Cisco Nexus 5596UP Switch
  • Cisco Nexus 5548P Switch
  • Cisco Nexus 6004 Switch
  • Cisco Nexus 5672UP Switch
  • Cisco Nexus 6001 Switch
  • Cisco Nexus 5548UP Switch
  • Cisco Nexus 56128P Switch
  • Cisco Nexus 5596T Switch

Known Affected Releases

7.0(2)N1(1)

Description (partial)

Symptom:
When the vPC port-channel is shut down on one side, the peer switch vPC remains up. But when vPC config is removed from shotdown port-channel, the peer switch suspends all the VLANs.

n6004-2# 2015 Feb  4 06:21:05 n6004-2 %ETHPORT-3-IF_ERROR_VLANS_SUSPENDED: VLANs 3001 on Interface port-channel30 are being suspended. (Reason: Peer does not have corresponding vPC)

Conditions:
none
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases