Cisco Bug: CSCus01616 - SWIM: Extended inventory collection failing in Catalyst 3850

Last Modified

May 20, 2016

Products (1)

  • Cisco Prime Infrastructure

Known Affected Releases

2.1-07

Description (partial)

Symptom:
Device inventory collection fails with message "Unable to collect the extended inventory info from device for Image Management Operations "


In cids.log, there will be a error log as follows:

indexCtdIn ]
[2014-09-22 11:53:33,795] [SWIM_Message_Processor_Thread] [service] [DEBUG] - Thread Id : [106] : IFM CIDS: [In IfmCIDSDeviceContext.getSnmpParams()]
[2014-09-22 11:53:33,795] [SWIM_Message_Processor_Thread] [service] [DEBUG] - Thread Id : [106] : IFM CIDS: [getParams() :: SNMP Version = 2c]
[2014-09-22 11:53:33,813] [SWIM_Message_Processor_Thread] [service] [ERROR] - Thread Id : [106] : IFM CIDS: [java.lang.NullPointerException]
[2014-09-22 11:53:33,813] [SWIM_Message_Processor_Thread] [service] [DEBUG] - Thread Id : [com.cisco.nm.xms.xdi.ags.system.CollectionFailedDeviceSensed: java.lang.NullPointerException] : IFM CIDS: [java.lang.NullPointerException]
[2014-09-22 11:53:33,813] [SWIM_Message_Processor_Thread] [service] [DEBUG] - Thread Id : [106] : IFM CIDS: [com.cisco.nm.xms.xdi.pkgs.SharedInventoryStack:SystemAGI_RFC1213_Mib:g$eval:into the method...]

Conditions:
The condition occurs in very few C3850 devices with peculiar entity-mib values.

The failure is caused by the order of in which MIB is read from the device in PI.

 "Switch 1 - WS-C3850-48P - Fixed Module 0" module refers to the chassis of the device that is not yet loaded PI and hence it triggers a null pointer exception.

Refer walk of entity-mib attached for reference.

ENTITY-MIB is loaded in PI in following order:
entPhysicalDescr.1	c3xxx Stack
entPhysicalDescr.2	Switch 1 - WS-C3850-48P - Fixed Module 0
entPhysicalDescr.3	Switch 1 Slot 1 FRULink Container
entPhysicalDescr.4	GigabitEthernet1/0/1
entPhysicalDescr.5	GigabitEthernet1/0/2
.
.
.
.
entPhysicalDescr.25	GigabitEthernet1/0/24
entPhysicalDescr.1000	WS-C3850-48P
entPhysicalDescr.1001	Switch 1 - WS-C3850-48P - Power Supply A Container:
.
.
.
.
.


And "Switch 1 - WS-C3850-48P - Fixed Module 0" refers to chassis which is not yet loaded by PI.

Here is the reference part of MIB:

entPhysicalContainedIn.1	0
entPhysicalContainedIn.2	1000   [Referring chassis by Switch 1 - WS-C3850-48P - Fixed Module 0]
entPhysicalContainedIn.3	1000
entPhysicalContainedIn.4	2
entPhysicalContainedIn.5	2
entPhysicalContainedIn.6	2
entPhysicalContainedIn.7	2
entPhysicalContainedIn.8	2





Device :  Catalyst 3850
SysOID :1.3.6.1.4.1.9.1.1641
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.