Cisco Bug: CSCur73330 - ISSU to 6.2(7) or (9) generates many exception log PS_FAIL: entries.

Last Modified

Mar 08, 2018

Products (1)

  • Cisco MDS 9000 Series Multilayer Switches

Known Affected Releases

6.2(7) 6.2(9)

Description (partial)

Symptom:
`show module internal exceptionlog`

********* Exception info for module 8 ********
exception information --- exception instance 2 ----
Module Slot Number: 8
Device Id         : 84
Device Name       : PowerSupply
Device Errorcode  : 0xc540220a
Device ID         : 84 (0x54)
Device Instance   : 02 (0x02)
Dev Type (HW/SW)  : 02 (0x02)
ErrNum (devInfo)  : 10 (0x0a)
System Errorcode  : 0x40380016 PS_FANFAIL: Fan inside the powersupply failed
Error Type        : Warning
PhyPortLayer      : Unknown
Port(s) Affected  : none
DSAP              : 39 (0x27)
UUID              : 24 (0x18)
Time              : Sun Nov  2 05:36:31 2014
                    (Ticks: 5456092F jiffies) 
 
exception information --- exception instance 3 ----
Module Slot Number: 8
Device Id         : 84
Device Name       : PowerSupply
Device Errorcode  : 0xc5402208
Device ID         : 84 (0x54)
Device Instance   : 02 (0x02)
Dev Type (HW/SW)  : 02 (0x02)
ErrNum (devInfo)  : 08 (0x08)
System Errorcode  : 0x40380014 PS_FAIL: Powersupply Failed or shutdown
Error Type        : Warning
PhyPortLayer      : Unknown
Port(s) Affected  : none
DSAP              : 39 (0x27)
UUID              : 24 (0x18)
Time              : Sun Nov  2 05:36:31 2014
                    (Ticks: 5456092F jiffies) 
 
exception information --- exception instance 4 ----
Module Slot Number: 8
Device Id         : 84
Device Name       : PowerSupply
Device Errorcode  : 0xc5402219
Device ID         : 84 (0x54)
Device Instance   : 02 (0x02)
Dev Type (HW/SW)  : 02 (0x02)
ErrNum (devInfo)  : 25 (0x19)
System Errorcode  : 0x40380024 PS_CAPACITY_CHANGE: PowerSupply changed capacity (possibly due to On/Off or power cord removal/insertion)
Error Type        : Minor error
PhyPortLayer      : Unknown
Port(s) Affected  : none
DSAP              : 39 (0x27)
UUID              : 24 (0x18)
Time              : Sun Nov  2 05:36:31 2014
                    (Ticks: 5456092F jiffies) 
 
exception information --- exception instance 6 ----
Module Slot Number: 8
Device Id         : 84
Device Name       : PowerSupply
Device Errorcode  : 0xc5401218
Device ID         : 84 (0x54)
Device Instance   : 01 (0x01)
Dev Type (HW/SW)  : 02 (0x02)
ErrNum (devInfo)  : 24 (0x18)
System Errorcode  : 0x40380023 PS_CAPACITY_DIFFER: Mismatched Capacity between both powersupplies
Error Type        : Minor error
PhyPortLayer      : Unknown
Port(s) Affected  : none
DSAP              : 39 (0x27)
UUID              : 24 (0x18)
Time              : Sun Nov  2 05:36:31 2014
                    (Ticks: 5456092F jiffies)

Conditions:
Firmware upgrades / ISSU
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.