2.2(1d)A

Description (partial)

Symptom:
UCS 6248 FI will not boot.

  Reason: Powered-down due to fan policy trigger
  System version: 5.2(3)N2(2.21d)
  Service: Fan dir mismatch

  `show logging nvram`
2014 Oct 22 16:49:42 SPCOLOUCS-A %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 0 seconds due to fan dir mismatch
2014 Oct 22 16:49:42 SPCOLOUCS-A %$ VDC-1 %$ Oct 22 16:49:42 %KERN-0-SYSTEM_MSG: [  213.461345] Shutdown Ports.. - kernel
2014 Oct 22 16:49:42 SPCOLOUCS-A %$ VDC-1 %$ Oct 22 16:49:42 %KERN-0-SYSTEM_MSG: [  213.502186]  writing reset reason 104, Fan dir mismatch - kernel
2014 Oct 22 16:55:15  %$ VDC-1 %$ %USER-2-SYSTEM_MSG: CLIS: loading cmd files begin  - clis
2014 Oct 22 16:55:18  %$ VDC-1 %$ Oct 22 16:55:17 %KERN-0-SYSTEM_MSG: [   10.688581] I2C - Mezz absent  - kernel
2014 Oct 22 16:55:24  %$ VDC-1 %$ %USER-2-SYSTEM_MSG: CLIS: loading cmd files end  - clis
2014 Oct 22 16:55:24  %$ VDC-1 %$ %USER-2-SYSTEM_MSG: CLIS: init begin  - clis
2014 Oct 22 16:55:44  %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 60 seconds due to fan dir mismatch
2014 Oct 22 16:55:49  %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 55 seconds due to fan dir mismatch
2014 Oct 22 16:55:54  %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 50 seconds due to fan dir mismatch
2014 Oct 22 16:55:59  %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 45 seconds due to fan dir mismatch
2014 Oct 22 16:56:04  %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 40 seconds due to fan dir mismatch
2014 Oct 22 16:56:09  %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 35 seconds due to fan dir mismatch
2014 Oct 22 16:56:14  %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 30 seconds due to fan dir mismatch
2014 Oct 22 16:56:19  %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 25 seconds due to fan dir mismatch
2014 Oct 22 16:56:24  %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 20 seconds due to fan dir mismatch
2014 Oct 22 16:56:29  %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 15 seconds due to fan dir mismatch
2014 Oct 22 16:56:32  %$ VDC-1 %$ %USER-2-SYSTEM_MSG: Running in PIO stats mode  - carmelusd
2014 Oct 22 16:56:33  %$ VDC-1 %$ %VDC_MGR-2-VDC_ONLINE: vdc 1 has come online 
2014 Oct 22 16:56:34 switch %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 10 seconds due to fan dir mismatch
2014 Oct 22 16:56:39 switch %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 5 seconds due to fan dir mismatch
2014 Oct 22 16:56:44 switch %$ VDC-1 %$  nsmgr: <<%PSS-2-PSS_INVALID_SIZE>> nsmgr: database /mnt/pss/nsmgr_nsmgr_saved_pss_data (.pss) has invalid size 0 (block size -1)
2014 Oct 22 16:56:45 SPCOLOUCS-A %$ VDC-1 %$ %PFMA-0-SYS_SHUTDOWN_FAN_DIR_MISMATCH: System shutdown in 0 seconds due to fan dir mismatch
2014 Oct 22 16:56:46 SPCOLOUCS-A %$ VDC-1 %$ Oct 22 16:56:46 %KERN-0-SYSTEM_MSG: [  214.982099] Shutdown Ports.. - kernel
2014 Oct 22 16:56:46 SPCOLOUCS-A %$ VDC-1 %$ Oct 22 16:56:46 %KERN-0-SYSTEM_MSG: [  215.021305]  writing reset reason 104, Fan dir mismatch - kernel Version: 5.2(3)N2(2.21d)

Conditions:
Booting 6248 FI following firmware upgrade to 2.2.1d

Customer confirmed that there were no environmental conditions which might cause a fan to rotate in the wrong direction.  

Customer held up a piece of string to confirm that the fans were pulling/pushing air in the same direction.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.