Description (partial)

Symptom:
Appliance may encounter application faults in the mail logs such as the following example:

Thu Sep 25 12:00:00 2014 Critical: An application fault occurred: ('_bencode.pyx _bencode.bencoder.compute_size (_bencode.c:2255)|206', "<type 'exceptions.OverflowError'>", 'value too large to convert to int', '[egg/injector.py run|1045] [egg/injector.py _run|1081] [egg/injector.py get_connection_data|493] [egg/SenderBase.py SenderBase_lookup|175] [_coro.pyx coro._coro.sched.with_timeout (coro/_coro.c:11529)|1086] [egg/SenderBase.py _doLookup|263] [egg/repeng.py query_repeng|235] [_bencode.pyx _bencode.encode (_bencode.c:3404)|319] [_bencode.pyx _bencode.bencoder.encode (_bencode.c:3223)|303] [_bencode.pyx _bencode.bencoder.compute_size (_bencode.c:2519)|235] [_bencode.pyx _bencode.bencoder.compute_size (_bencode.c:2255)|206]')

Once these application faults start occurring, all SenderBase Reputation Score (SBRS) lookups will fail until the appliance is rebooted.

Conditions:
This issue only occurs in very high traffic environments when the appliance has not been rebooted for a long period of time.  This defect will not occur unless at least 2 billion connections have been received during the current uptime of the appliance.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.