Description (partial)

Symptom:
Prime Infrastructure 2.1.1 shows device Nexus 5548P in status "Partial Collection Failure" due to MIB object reference missing.
On a Nexus 5000 when polling (entPhysicalContainedIn) 1.3.6.1.2.1.47.1.1.1.1.4, the returned values may be erroneous.
One of the values returned gives back an non-existing index:
entPhysicalContainedIn.24 = INTEGER: 220

Conditions:
This issue is observed when running 6.0(2)N1(2).

Related Community Discussions

Cisco Prime Infrastructure 2.1.1 SNMP Connectivity Failed with N5K
Hi all,   I'm facing a strange issue with CPI 2.1.1 and N5K 5596UP NX-OS   5.2(1)N1(8a) , for some reason I'm getting a SNMP Connectivity Failed, here are my T-SHOOT that I've done so far:   1. increasing the timeout and retries - didn't help. 2. change from SNMP v3 to SNMP v2 - didn't help. 3. tried to stop the SNMP process in   N5K with the command: no snmp-server protocol disable - its seems that the command not working. 4. stop/start the process. 5. reload the CPI.   also the odd thing is that ...
Latest activity: Nov 19, 2014
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.