Guest

Preview Tool

Cisco Bug: CSCuq34497 - N5k: VPC Consistency Failure after changing the port-profiles on N1k.

Last Modified

Sep 09, 2019

Products (7)

  • Cisco Nexus 5000 Series Switches
  • Cisco Nexus 5596UP Switch
  • Cisco Nexus 5548P Switch
  • Cisco Nexus 5020 Switch
  • Cisco Nexus 5548UP Switch
  • Cisco Nexus 5010 Switch
  • Cisco Nexus 5596T Switch

Known Affected Releases

5.2(1)N1(7)

Description (partial)

Symptom:
VPC goes into a Consistency Failure after changing the port-profiles on N1k

The port-profile change on the Nexus 100 triggers the operational key to change, which leads to a LAG ID changes on the VPC Primary.

The consistency check will fail on the secondary since the secondary is having a different LAG-ID.

Due to consistency failure and VPC graceful consistency check enabled, the port is suspended and never brought up

Conditions:
Changing the port-profle on Nexus 1k may lead to a consistency check failure when using VPC