Symptom:
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110] Building set PDUs for operation
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110]     MIB lookup, OID for: classificationType = 1.3.6.1.4.1.14179.2.1.7.1.25.8.31.243.224.77.111
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110] Building set PDUs for main table: 1.3.6.1.4.1.14179.2.1.7
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110] All attributes fit into one PDU
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110] Creating set PDU, size 1
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110]     Set class=com.cisco.server.managedobjects.wlan.RogueAp, attr=classificationType
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110]     Field Name = classificationType
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110]     MibAttribute Type = INT, INT32
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110]     Value = 2
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110] Number of PDUs = 1 for class com.cisco.server.managedobjects.wlan.RogueAp
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110] ModifyObject invoked
07/03/14 16:23:40.001 TRACE [http-bio-443-exec-20] [10.104.178.110] PingSysObjectId invoked
07/03/14 16:23:40.006 TRACE [http-bio-443-exec-20] [10.104.178.110] Sending PDU 1
07/03/14 16:23:40.078 INFO  [http-bio-443-exec-20] [10.104.178.110] SNMP request generated error response: SET[requestID=520537610, errorStatus=Success(0), errorIndex=0, VBS[1.3.6.1.4.1.14179.2.1.7.1.25.8.31.243.224.77.111 = 2]]
07/03/14 16:23:40.078 INFO  [http-bio-443-exec-20] [10.104.178.110] SNMP error response: RESPONSE[requestID=520537610, errorStatus=Inconsistent value(12), errorIndex=1, VBS[1.3.6.1.4.1.14179.2.1.7.1.25.8.31.243.224.77.111 = 2]]
07/03/14 16:23:40.078 ERROR [http-bio-443-exec-20] [10.104.178.110] Invalid attribute value com.cisco.server.managedobjects.wlan.RogueAp.classificationType, error status = Inconsistent value
07/03/14 16:23:42.094 TRACE [roguetask-4] [10.104.178.110] Walking class com.cisco.server.managedobjects.wlan.RogueAp

Conditions:
In case of setting Malicious or Unclassified from one another.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.