Cisco Bug: CSCup64117 - SystemMgmtBus test not restarted after fan/PSU hot swap

Last Modified

Feb 15, 2018

Products (1)

  • Cisco Nexus 7000 Series Switches

Known Affected Releases

6.2(6.10)S0

Description (partial)

Symptom:The diagnostic test is not restarted after a replacement fan or power supply unit is hot swapped for a failed unit. The SystemMgmtBus diagnostic test shows the new unit as untested.

The following is a sample of a message that indicates the SystemMgmtBus failed for a power supply:

%DEVICE_TEST-2-POWER_SUPPLY_FAIL: Module 6 has failed test SystemMgmtBus 20 times on System Mgmt Bus for chassis Power Supply instance 2 due to error Power supply is found to be bad error number 0x00000002

If the diagmgr logging level is 5(notifications) or lower (numerically) the following message will be seen:

%DIAGMGR-5-HM_STOP: Disabling health monitoring test <SystemMgmtBus> for Module <5>

  switch# show diagnostic result module 6 test 10 detail
            ...
        10) SystemMgmtBus .
            ...
        Chassis Fan       1  2  3
         ---------------------------------------------------------------------
                          .  .  .
        PS                1  2  3  4  5  6  7  8
         ---------------------------------------------------------------------
                          .  .  .  U  .  .  .  .

Conditions:This issue only applies to Nexus 7000 with Supervisor2, Nexus 7700 with Supervisor3 and MDS 9700 director series switches. It does not occur when the system is booted.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.