Description (partial)
Symptom: Prime Infrastructure polls device uptime using the SNMP OID sysUpTime (1.3.6.1.2.1.1.3), which counts TimeTicks and has a maximum value of: 497 days, 2 hours, 27 minutes and 52.95 seconds It is pretty common for Networking Devices to have over 1 or 2 years of Up time. PI 1.x, 2.x, 3.x should query the already available larger OIDs in order to provide a more accurate system Up time value via SNMP: SNMP-FRAMEWORK-MIB: snmpEngineTime = maximum value 68 Years, 03:14:07. Conditions: Devices monitored with Prime Infrastructure 1.x, 2.x, 3.x