Cisco Bug: CSCup24169 - GTP Path failure after false detection of restart counter change

Last Modified

Dec 25, 2016

Products (1)

  • Cisco ASR 5000 Series

Known Affected Releases

14.0

Description (partial)

Symptom:
In the logs below you can see that the new RC number is lower than the old RC

2014-May-31+17:17:10.644 [egtpmgr 143059 info] [1/1/4417 <egtpinmgr:1> egtpmgr_pm.c:2526] [context: SAEGW, contextID: 2]  [software internal system critical-info syslog] context: SAEGW, service : SGW_S11_CTRL_SVC, interface-type: interface-sgw-ingress, self addr: 166.137.15.209, GTP-C path failure for peer 172.26.118.198, peer old restart counter:221,peer new restart counter: 180, peer session count: 11701, Reason: Create Session Req Restart Counter changed

Conditions:
Issue seen on multiple nodes
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.