Description (partial)

Symptom:
Symptom:
In the MDS 9000 Configuration Guide, the Power Supply Redundancy Modes need to be updated with the full list of modes available.  http://www.cisco.com/c/en/us/td/docs/switches/datacenter/mds9000/sw/6_2/configuration/guides/fundamentals/b_Cisco_MDS_9000_Series_NX-OS_Fundamentals_Configuration_Guide_Release_6_x/b_Cisco_MDS_9000_Series_NX-OS_Fundamentals_Configuration_Guide_Release_6_chapter_01010.html#task_7BB98A5EEBE949E09FF5197B074C565D

Conditions:
Conditions:

The Configuration Guide only lists Redundant and Combined modes. The current full list of modes available is combined, redundant, insrc-redundant, and ps-redundant.
If the switch is in one of the redundant modes, the existing power supplies cannot be in 'shutdown mode' or the operational mode from 'show environment power' will display as 'non-redundant'.

Switch(config)# power redundancy-mode ?
  combined         Configure power supply redundancy mode as combined
  insrc-redundant  Configure power supply redundancy mode as grid/AC input
                   source redundant
  ps-redundant     Configure power supply redundancy mode as PS redundant
  redundant        Configure power supply redundancy mode as InSrc and PS
                   redundant
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.