Cisco Bug: CSCuo49066 - Wrong trigger values for OTU2_XP cards client ports.
Last Modified
Jan 25, 2019
Products (1)
- Cisco ONS 15454 Series Multiservice Provisioning Platforms
Known Affected Releases
9.60 9.601 9.602 9.603 9.604 9.605 9.606 9.607
Description (partial)
Symptom: When 10-2012-0x XFPs plugged in, wrong TCA thresholds are populated for the 10 GIGE payload on the OTU2XP card. It shall result in unnecessary alarms like 'High Rx Power', 'Low Rx power' Conditions: Conditions: 1) 10 GIGE payload provisioned as client port in OTU2XP card. 2) Plugin a ONS-XC-10G-S1 pluggable with part number as 10-2012-0x (x denotes all the family of those pluggables 01, 02, 03, 04) 3) Under the Optics Thresholds pane, the values of High Rx Power are marked as -7 dBM and Low Rx Power as -24dbM 4) T-RX-PWR-MAX condition raised in CTC for 15min threshold value
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.
Bug Details Include
- Full Description (including symptoms, conditions and workarounds)
- Status
- Severity
- Known Fixed Releases
- Related Community Discussions
- Number of Related Support Cases