Cisco Bug: CSCuo46080 - onep ACL Updated When Flow Add Fails
Last Modified
Dec 03, 2017
Products (1)
- Cisco Extensible Network Controller (XNC)
Known Affected Releases
1.0(0)
Description (partial)
Symptom: When configuring a static flow on a onePK node without specifying a input interface, the following error is seen in XNC: [http-bio-8443-exec-3] WARN c.c.c.p.o.s.internal.PolicyServices - Match on All interfaces not supported for ONEP Nodes However, the onep ACL on the node is still updated: nexus3064# sh access-l onep-acl-4 IPV4 ACL onep-acl-4 statistics per-entry 2052096 deny ip any 5.5.5.5/32 ethertype 0x800 priority 65035 Conditions: - Cisco Extensible Network Controller (XNC) 1.5.0 - Static flow configuration on a onePK node - Flow doesn't include input interface
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.
Bug Details Include
- Full Description (including symptoms, conditions and workarounds)
- Status
- Severity
- Known Fixed Releases
- Related Community Discussions
- Number of Related Support Cases