Guest

Preview Tool

Cisco Bug: CSCuo31148 - B200 M2 servers experienced multiple HDD failures after upgrade to 2.1.3

Last Modified

Mar 06, 2018

Products (1)

  • Cisco Unified Computing System

Known Affected Releases

2.1(3b)A

Description (partial)

Symptom:
B200 M2 servers experience multiple HDD failures after upgrade to 2.1.3 build.

A fault is raised in UCSM:

Severity: Major
Code: F0181
Last Transition Time: 2014-01-13T15:06:31.962
ID: 837536
Status: None
Description: Local disk 2 on server 2/6 operability: inoperable. Reason: Firmware Detected Drive Fault
Affected Object: sys/chassis-2/blade-6/board/storage-SAS-1/disk-2
Name: Storage Local Disk Inoperable
Cause: Equipment Inoperable
Type: Equipment
Acknowledged: No
Occurrences: 1
Creation Time: 2014-01-13T15:06:31.962
Original Severity: Major
Previous Severity: Major
Highest Severity: Major

Faults are transient and clear out automatically. Here is the entry seen in SEL logs:

5:2014 Jan 13 15:06:23:2.1(3a):selparser:-: selparser.c:668: # D0 02 00 00 01 02 00 00 BE D6 D3 52 20 00 04 0D 22 00 00 00 04 01 FF FF # 2d0 | 01/13/2014 15:06:22 | CIMC | Drive slot(Bay) SAS1_FAULT #0x22 | Predictive Failure asserted | Asserted

Conditions:
B200 M2 on 2.1.3
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.