Cisco Bug: CSCuo02686 - Show module Status not descriptive as to why it is in powered-dn status
Last Modified
Mar 01, 2019
Products (1)
- Cisco MDS 9000 Series Multilayer Switches
Known Affected Releases
6.2(5a) 6.2(9)FM(0.48)
Description (partial)
6.2(5a) hardware ejector enable (Default) MDS-9710-1(config)# hardware ejector enable MDS-9710-1(config)# 2014 Mar 25 07:58:51 rtp-san-33-18-9710-1 %PLATFORM-2-MODULE_EJECTOR_POLICY_ENABLED: All Ejectors closed for module 1. Ejector based shutdown enabled 2014 Mar 25 07:58:51 MDS-9710-1 %PLATFORM-2-MODULE_EJECTOR_POLICY_ENABLED: All Ejectors closed for module 2. Ejector based shutdown enabled 2014 Mar 25 07:58:51 MDS-9710-1 %PLATFORM-2-MODULE_EJECTOR_POLICY_ENABLED: All Ejectors closed for module 5. Ejector based shutdown enabled 2014 Mar 25 07:58:51 MDS-9710-1 %PLATFORM-2-XBAR_EJECTOR_POLICY_ENABLED: All Ejectors closed for Xbar 1. Ejector based shutdown enabled 2014 Mar 25 07:58:51 MDS-9710-1 %PLATFORM-2-XBAR_EJECTOR_POLICY_ENABLED: All Ejectors closed for Xbar 2. Ejector based shutdown enabled 2014 Mar 25 07:58:51 MDS-9710-1 %PLATFORM-2-XBAR_EJECTOR_POLICY_ENABLED: All Ejectors closed for Xbar 3. Ejector based shutdown enabled MDS-9710-1# show mod Mod Ports Module-Type Model Status --- ----- ----------------------------------- ------------------ ---------- 1 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok 2 0 Unknown Module powered-dn 5 0 Supervisor Module-3 DS-X97-SF1-K9 active * 6 0 Supervisor Module-3 DS-X97-SF1-K9 ha-standby Pressed button on standby slot 6 rtp-san-33-18-9710-1# 2014 Mar 25 08:18:27 rtp-san-33-18-9710-1 %PLATFORM-2-SINGLE_EJECTOR_STAT_CHANGED: Ejector's status in slot 6 has changed, Ejector is OPEN 2014 Mar 25 08:18:28 rtp-san-33-18-9710-1 %PLATFORM-2-MOD_REMOVE: Module 6 removed (Serial number JAE171008AR) rtp-san-33-18-9710-1# show mod Mod Ports Module-Type Model Status --- ----- ----------------------------------- ------------------ ---------- 1 48 2/4/8/10/16 Gbps Advanced FC Module DS-X9448-768K9 ok 2 0 Unknown Module powered-dn 5 0 Supervisor Module-3 DS-X97-SF1-K9 active * 6 0 Supervisor Module-3 powered-up ---- -> standby sup went into power-up status -> status light is red blinking all other lights off Symptom: After supervisor is removed due to "hardware ejector enable", the status of the sup is shown in powered-dn status. Conditions: Supervisor single ejector lever release button pushed, MDS 9710 NX-OS 6.2(5a) with "hardware ejector enable" configured. Supervisor goes to powered-dn status.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.
Bug Details Include
- Full Description (including symptoms, conditions and workarounds)
- Status
- Severity
- Known Fixed Releases
- Related Community Discussions
- Number of Related Support Cases