Guest

Preview Tool

Cisco Bug: CSCuo01245 - Zoneset activation & commit fails on MDS 9710

Last Modified

Apr 02, 2020

Products (1)

  • Cisco MDS 9000 Series Multilayer Switches

Known Affected Releases

6.2(7) 6.2(7)S44

Description (partial)

Symptom:
Zoneset commit operations initiated from an MDS 9710 fail with the following error:

  switch# show zone status vsan 1
  ...
  Status: Commit failed [Error: SFC retry exceeded Dom 1]:

Conditions:
This issue only occurs when a zone change is committed from an MDS 9710 switch populated with DS-X9448-768K9 modules.

The onset depends on the cumulative size of zonesets commits from all VSANs. A low volume of large zoneset commits or large volume of small commits or any combination in between will trigger the issue. Once hit it will persist until recovery steps are taken.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.