Guest

Preview Tool

Cisco Bug: CSCun95096 - Capability catalog incorrectly classifies SSD drive as HDD

Last Modified

Mar 09, 2018

Products (1)

  • Cisco Unified Computing System

Known Affected Releases

2.2(1b)T

Description (partial)

Symptom:
ATA STEC MACH16 M16ISD2-100UCU-C01-TKF has an incorrect capability catalog technology field set to "HDD" but it should be "SSD".  ATA STEC MACH16 M16ISD2-100UCU model has the technology field correctly  set to "SSD"  When a customer has raid 1 volume defined in service profile, the service profile associating fails with an error stating that the raid configuration is invalid because different drive technologies are attempting to be mixed, if both model types are in use.  Both models have the same PID: UCS-SSD100GI1F104

Conditions:
Two slightly different model numbers of SSD drives with same PID are categorized with different technology types
ATA STEC MACH16 M16ISD2-100UCU :Technology = SSD
ATA STEC MACH16 M16ISD2-100UCU-C01-TKF   :Technology= HDD
Both share same PID: UCS-SSD100GI1F104
ATA STEC MACH16 M16ISD2-100UCU-C01-TKF has an incorrect capability catalog technology field set to "HDD" but it should be "SSD"

Customers may have both drives present in a raid 1 configuration