Guest

Preview Tool

Cisco Bug: CSCun60625 - PIXM error when deleting VLAN and recreating which has HIF PC member

Last Modified

Feb 06, 2017

Products (8)

  • Cisco Nexus 7000 Series Switches
  • Cisco Nexus 7000 10-Slot Switch
  • Cisco Nexus 7000 4-Slot Switch
  • Cisco Nexus 7700 6-Slot Switch
  • Cisco Nexus 7000 18-Slot Switch
  • Cisco Nexus 7700 18-Slot Switch
  • Cisco Nexus 7700 10-Slot Switch
  • Cisco Nexus 7000 9-Slot Switch

Known Affected Releases

6.2(6) 6.2(6a) 6.2(7.19)S0

Description (partial)

Symptom:
Upon VLAN delete followed by VLAN creation the following syslog appears on console:

2014 Mar  6 11:52:32 tango %PIXM-3-PIXM_SYSLOG_MESSAGE_TYPE_ERR: Process:VDC-1-pixm_vl.Please collect logs as per: http://<url> .TCB_RID:0x57,TXN_Type:51,Status:0x0,Error_Type:0x20.

Conditions:
When feature mvrp is enabled and fex ports are present, modification to the vlan database results in the syslog described in the sympthoms section. Mvrp is trying to program the fex port to prune/unpruned the vlan.

There is no side effect since the message is ignored by the pix module.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.