Guest

Preview Tool

Cisco Bug: CSCun30630 - Teroldego wrong severity on LOS -D alarm

Last Modified

Oct 31, 2014

Products (1)

  • Cisco ONS 15454 Series Multiservice Provisioning Platforms

Known Affected Releases

10.01

Description (partial)

Symptom:
When LOS-D alarm is raised without being demoted by LOS alarm (typically, when there is no loss of span connectivity but DFB lasers are shutdown by OSRI commands), its severity is wrong

Conditions:
1. Node with CTP card
2. Span connected to CTP card is not broken
3. LOS-D alarm is raised, because of a DFB failure or OSRI maintenance in place
4. OSC or Payload signals are still able to keep their safety cycle closed.