Guest

Preview Tool

Cisco Bug: CSCun12709 - Monitoring Key is not send when the quota breaches 75%

Last Modified

Dec 24, 2016

Products (1)

  • Cisco Policy Suite for Mobile

Known Affected Releases

5.3.4.3

Description (partial)

Symptom:
I'm trying to configure one use case (Quota use case) for testing between Huawei DPI (SIG) and Cisco QPS 5.3.4.
This use case is a quota use case, the subscriber have 2 quotas:
•	Main Quota: 200MB
•	Small Quota: 1024 Bytes, this quota is required in order for the Huawei SIG to be notified that the user got the one time redirection (when this quota is 0, DPI will know about the redirection).

The use case call flow should be as below:

1-	On initial connection:
CCRi from SIG
CCAi to SIG with: Monitor Key 1001 with quota dosage of 5MB, Rule Name  14:200001


2-	Normal CCRu's and CCAu's till the user reaches out 75% of his quota
3-	On 75%:
CCRu from SIG
CCAu to SIG with: Monitor Key 1002 with small quota dosage of 1024 Bytes, Rule Name: 14:200013, One time redirect server info (Redirect address type, One time redirection, URL)

4-	After 75% threshold is breached, the small quota named ?Redirection? (1024 Bytes) should be consumed and the user continues with normal CCRu's and CCAu's for the main quota (200MB)
5-	On 100%:
CCRu from SIG
CCAu to SIG with: Permanent redirect server info (Redirect address type, Permanent redirection, URL), Rule Name: 1:200003
The previous 2 rules (14:200001 and 14:200013) should be removed


Everything is working fine except for one thing: 
On 75% the PCRF is sending the Rule name and the redirect server info , but it is not sending the MK 1002 and the small quota.

Conditions:
On 75% the PCRF is sending the Rule name and the redirect server info , but it is not sending the MK 1002 and the small quota.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.