Guest

Preview Tool

Cisco Bug: CSCum89468 - Erroneous minor fault F1083: FCoE or FC uplink is down on Vsan

Last Modified

Nov 27, 2018

Products (1)

  • Cisco Unified Computing System

Known Affected Releases

2.2(1b)A

Description (partial)

Symptom:
After upgrade to 2.2(1b), Non-trunking port-channel logs Erroneous minor fault F1083: FCoE or FC uplink is down on Vsan # for any Vsan that is configured under that fabric or global Vsan except for the Vsan the port-channel is configured to use. So for example,  if there are multiple vsans under Fabric A, or global Vsans, but the FC port channel under Fabric A is configured only for Vsan 10, these errors will log for all other Vsans against that port channel except vsan 10.

Conditions:
UCS 2.2(1b) with FC port channel configured in non-trunking mode. 
Multiple Vsans under either the specific San cloud Fabric, or global Vsan.
All FC ports in the port channel are up and operational.