Cisco Bug: CSCum24037 - "show hw-module fpd location all" hinting to downgrade rommon with v2.0

Last Modified

Mar 08, 2018

Products (1)

  • Cisco ASR 9000 Series Aggregation Services Routers

Known Affected Releases

4.3.1.BASE

Description (partial)

The ROMMON image downgrade from versions 2.00 and above is not supported on certain cards.
This is prevent any future hardware / software incompatibility.
This is attributed to CSCug38404

Symptom:
1. '#admin show hw-module fpd' CLI shows rommon image version 2.00 or above  
2. The 'Upg/Dwn' column for the image is marked as 'Yes' in the CLI output
3. On attempting the fpd upgrade operation, the operation is unsuccessful.
4. A syslog message indicating that the rommon version is severly up-rev:
   LC/0/3/CPU0:Dec 19 05:56:59.697 : rommon_fpd_agent[312]: %PLATFORM-UPGRADE_FPD-4-UP_REV : rommon instance 0 is severely up-rev (V2.00), downgrade to (V1.29). Use the "upgrade hw-module fpd" CLI in admin mode

Conditions:
1. '#admin show hw-module fpd' CLI shows rommon image version 2.00 or above  
2. The 'Upg/Dwn' column for the image is marked as 'Yes' in the CLI output
3. '#admins show fpd package' shows the rommon version for the card type to be less that 2.00
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.