Description (partial)
Symptom: ISIS adjacencies will not form for Overlay1 with the trigger provided in the Conditions section. n7k-tb09-bldchk1-edge# sh otv isis adjacency OTV-IS-IS process: default VPN: Overlay1 -------> All the adjacencies on overlay1 are down. OTV-IS-IS adjacency database: System ID SNPA Level State Hold Time Interface Site-ID OTV-IS-IS process: default VPN: Overlay2 OTV-IS-IS adjacency database: System ID SNPA Level State Hold Time Interface Site-ID 0000.0000.0003 0026.980b.fc42 1 UP 00:01:23 Overlay2 0000.0000.0001 0000.0000.0001 4055.3904.67c2 1 UP 00:01:36 Overlay2 0000.0000.0003 0000.0000.0002 4055.3923.dac2 1 UP 00:01:26 Overlay2 0000.0000.0002 Conditions: Trigger: Change the join interface for Overlay1 to the same join interface for Overlay2. This is essentially allowing two different Overlays to share the same join interface. n7k-tb09-bldchk1-edge(config)# interface Overlay1 n7k-tb09-bldchk1-edge(config-if-overlay)# no otv join-interface Ethernet3/9/3 n7k-tb09-bldchk1-edge(config-if-overlay)# otv join-interface Ethernet3/12/3 <=== Join interface of overlay2
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.
Bug Details Include
- Full Description (including symptoms, conditions and workarounds)
- Status
- Severity
- Known Fixed Releases
- Related Community Discussions
- Number of Related Support Cases