Guest

Preview Tool

Cisco Bug: CSCul44714 - EMC-ENTRANCE:QLE8362 missed sending NOPs after host reboot - ER111610

Last Modified

Aug 16, 2017

Products (1)

  • Cisco MDS 9000 Series Multilayer Switches

Known Affected Releases

6.2(5)MD

Description (partial)

Symptom:
ER Description : If immediate data that has length that is not 8 byte aligned is sent, iSCSI does not handle it properly and TOE does not send pdu.

Root Cause : iSCSI is not checking for unaligned data length in immediate data case.

Conditions:
ER Description : If immediate data that has length that is not 8 byte aligned is sent, iSCSI does not handle it properly and TOE does not send pdu.

Root Cause : iSCSI is not checking for unaligned data length in immediate data case.

Solution : Check for unaligned data in immediate data case and use transmit slow routine will deals with that by adding pad.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.