Guest

Preview Tool

Cisco Bug: CSCul39006 - C240-M3 UCSM Integrated Emulex UCSC-PCIE-ESFP OneConnect OCe11102

Last Modified

Apr 24, 2015

Products (1)

  • Cisco Unified Computing System

Known Affected Releases

1.5(2)

Description (partial)

Symptom:
C240-M3 UCSM Integrated Emulex UCSC-PCIE-ESFP OneConnect OCe11102 FIP Keepalive - FKA misses causing lost FLOGI and vFC down.

Conditions:
C240-M3 UCSM Integrated Emulex UCSC-PCIE-ESFP OneConnect OCe11102 after an undetermined amount of time, the vFC interfaces lose their FLOGI due to FKA misses as seen with 'show platform software fcoe_mgr event-history errors'.


(nxos)# show platform software fcoe_mgr event-history errors 
1) Event:E_DEBUG, length:68, at 691362 usecs after Wed Nov 13 13:28:18 2013
    [102] fcoe_mgr_vfc_ac_eval(4441): DEBUG:shut: log_port_down vfc2499  < ------- port down


2) Event:E_DEBUG, length:86, at 684191 usecs after Wed Nov 13 13:28:18 2013
    [102] fcoe_mgr_vfc_ac_eval(4454): DEBUG:shut:Sending event to delete protos of vfc2499


3) Event:E_DEBUG, length:150, at 656503 usecs after Wed Nov 13 13:28:18 2013
    [102] fcoe_mgr_del_vn_port_to_revpin_db(981): fcoe_mgr_del_vn_port_to_revpin_db:vfc2499 vsan[121] Invalid pinned BP fcid[7929976] ret_val [0x42070006] 

4) Event:E_DEBUG, length:154, at 656272 usecs after Wed Nov 13 13:28:18 2013
    [102] fcoe_mgr_del_vn_port_to_revpin_db(987): fcoe_mgr_del_vn_port_to_revpin_db: Could not get p_vfc for pinn_bp if_index [0x4000064] ret_val [0x42070006] 

5) Event:E_DEBUG, length:150, at 655680 usecs after Wed Nov 13 13:28:18 2013
    [102] fcoe_mgr_vfc_ac_eval(4527): BRINGDOWNVFC: vfc2499 NOT Pinnned to OR force-down VNP [4000064] event to proto: Proto RID 121, 00:90:fa:04:92:a5 : 


6) Event:E_DEBUG, length:109, at 655673 usecs after Wed Nov 13 13:28:18 2013
    [102] fcoe_mgr_vfc_ac_eval(4464): DEBUGCVL: Adding EV_DELETE event to proto: Proto RID 121, 00:90:fa:04:92:a5


7) Event:E_DEBUG, length:86, at 655665 usecs after Wed Nov 13 13:28:18 2013
    [102] fcoe_mgr_vfc_ac_eval(4454): DEBUG:shut:Sending event to delete protos of vfc2499


8) Event:E_DEBUG, length:90, at 635189 usecs after Wed Nov 13 13:28:18 2013
    [102] fcoe_mgr_proto_ac_eval(1778): Bringing down PROTO 1e0009c2 due to truly missing fka  < ------ missing FIP Keepalive


9) Event:E_DEBUG, length:68, at 659826 usecs after Tue Nov 12 10:53:23 2013
    [102] fcoe_mgr_vfc_ac_eval(4441): DEBUG:shut: log_port_down vfc2499 


10) Event:E_DEBUG, length:86, at 658688 usecs after Tue Nov 12 10:53:23 2013
    [102] fcoe_mgr_vfc_ac_eval(4454): DEBUG:shut:Sending event to delete protos of vfc2499


11) Event:E_DEBUG, length:86, at 654919 usecs after Tue Nov 12 10:53:23 2013
    [102] fcoe_mgr_vfc_ac_eval(4454): DEBUG:shut:Sending event to delete protos of vfc2499
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.