Cisco Bug: CSCul38790 - Tracebacks after deconfiguring Frame Relay interfaces
Last Modified
Jan 24, 2017
Products (1)
- Cisco 7600 Series Routers
Known Affected Releases
12.2(33)SXJ2
Description (partial)
Symptom: Customer reported the following non-service impacting syslog and traceback: 1. %SIP200_MP-4-PAUSE: Non-master CPU is suspended for too long, from 0x406E1D40(2) to 0x406E2710 for 380023 CPU cycles. 2. traceback 406D6048 4050A8E8 4050CD5C 4058B54C 4059F3F4 40593A58 40594520 402EB198 402EB184 in fib_process_vip_mlp_config_update: 0x406D6048:fib_process_vip_mlp_config_update(0x406d5f18)+0x130 0x4050A8E8:fib_process_ipfib_xdr(0x4050a80c)+0xdc 0x4050CD5C:ipfib_lc_xdr_msg_decode(0x4050cd3c)+0x20 0x4058B54C:xdr_client_decode_data(0x4058b3cc)+0x180 0x4059F3F4:xdr_ipc_unpack_received_data(0x4059ed3c)+0x6b8 0x40593A58:xdr_lc_service_rcv_data_ipcQ(0x40593a14)+0x44 0x40594520:xdr_lc_background(0x4059442c)+0xf4 0x402EB198:r4k_process_dispatch(0x402eb184)+0x14 0x402EB184:r4k_process_dispatch(0x402eb184)+0x0 Conditions: Deconfiguration of Frame Relay interfaces
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.
Bug Details Include
- Full Description (including symptoms, conditions and workarounds)
- Status
- Severity
- Known Fixed Releases
- Related Community Discussions
- Number of Related Support Cases