Cisco Bug: CSCul35367 - 9.81-WSE: OC192 traffic not up with OTU2XP/Carpegna interop
Last Modified
Jun 06, 2014
Products (1)
- Cisco ONS 15454 Series Multiservice Provisioning Platforms
Known Affected Releases
9.810
Description (partial)
Symptom: 9.81-WSE-OC192: OTU2XP interop is not working Setup: ****** OTU2XP(client loopback) P2=====Trunk(P4)----------Trunk======WSE(OC192) Note: Encryption disabled, standard FEC on both ends Conditions: Problem: ******** PTIM and LOF are reported on OTU2XP trunk port on interop with WSE card. There are no OTN level alarms or errors Trouble shooting done: ****************** 1] Interop between Carpegna and OTU2XP works fine.( No alarms seen) 2] Interop between Carpegna and Rahasya : PTIM reproted on carpegna trunk port but no LOF 3] Disabled OTN on OTU2XP trunk and connected OC192 client of Rahasya to OTU2XP trunk port No alarms are reported throughout 4] Tried with different port pairs on WSE (1-2, 9-10). Put WSE in a different slot and configured fresh payload, still the same issue is seen
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.
Bug Details Include
- Full Description (including symptoms, conditions and workarounds)
- Status
- Severity
- Known Fixed Releases
- Related Community Discussions