Cisco Bug: CSCul18871 - 8GFC Y-cable switching causes 18-19s traffic drop while brocade interop
Last Modified
Oct 08, 2015
Products (1)
- Cisco ONS 15454 Series Multiservice Provisioning Platforms
Known Affected Releases
10.10 10.101 9.605
Description (partial)
Symptom: When protected 8GFC interops with Brocade, for any switch request (AUTO/MAN) causes a traffic drop of 18-19s. Conditions: Steps to Reproduce ================== 1. Have AR-XPE with TXP-HIGH, 8GFC on near end as well far end node 2. Create Y-cable and feed the traffic. 3. Ensure that the end to end traffic is fine. 4. Perform Y-cable switching and check the traffic , ISL status. Here you shall see a switch hit of 18-19s for MAN/AUTO SRs. Expected Behavior ================= No issues shall be seen while performing the above steps
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.
Bug Details Include
- Full Description (including symptoms, conditions and workarounds)
- Status
- Severity
- Known Fixed Releases
- Related Community Discussions
- Number of Related Support Cases