Cisco Bug: CSCuj91626 - Execute SQL Server Script activity fail when multiple SQL statements run

Last Modified

Jan 25, 2017

Products (5)

  • Cisco Process Orchestrator
  • Cisco Intelligent Automation for Cloud 4.1
  • Cisco Intelligent Automation for Cloud 4.0
  • Cisco Process Orchestrator 3.0
  • Cisco Intelligent Automation for SAP 3.0

Known Affected Releases

3.0.0

Description (partial)

Symptom:
When executing multiple SQL statements in an Execute SQL Script activity, the activity may fail with the error  "There is already an open DataReader associated with this Command which must be closed first".

Conditions:
The error only happens when 1) multiple SQL statements are included in the Execute SQL Script activity, and 2) there are data rows returned by one SQL statement.

The DataReader needs to be closed before the DB command can open the next DataReader.