Guest

Preview Tool

Cisco Bug: CSCuj63626 - TES 5.3.1 Certain 10-character aliases result in error when transported

Last Modified

Jul 25, 2014

Products (1)

  • Cisco Tidal Enterprise Transporter

Known Affected Releases

5.3.1

Description (partial)

Symptom:
If an alias conflict occurs in the destination database of a transport in Transporter 5.3.1, the following 10-character aliases return an error and do not transport the selected job.

8811AAAAAF
5835AABAAF
4642AAAAAE
9361AAAAAF
2814BABCBA

Error:  "Unable to insert the record String or binary data would be truncated"

Conditions:
Found in 5.3.1.429 Transporter

Recreate steps:
1.) Create two jobs
2.) update the two jobs aliases to be identical in the database, and to be 10 characters in length using the example aliases above.
3.) Transport job 1, no problem
4.) Transport job 2, verify that it will change the alias, error pops up.
Bug details contain sensitive information and therefore require a Cisco.com account to be viewed.

Bug Details Include

  • Full Description (including symptoms, conditions and workarounds)
  • Status
  • Severity
  • Known Fixed Releases
  • Related Community Discussions
  • Number of Related Support Cases
Bug information is viewable for customers and partners who have a service contract. Registered users can view up to 200 bugs per month without a service contract.