Guest

Preview Tool

Cisco Bug: CSCui98180 - HotSpot "sensor 2" in 3750X has incorrect Yellow threshold value

Last Modified

Feb 22, 2014

Products (1)

  • Cisco Catalyst 3750-X Series Switches

Known Affected Releases

n/a

Description (partial)

Symptom:
Symptom:
HotSpot sensor 2 in 3750X has incorrect Yellow threshold value.
Which can causes false SNMP alarms on SNMP Server. New  Yellow Threshold values will be set to address this issue.

Conditions:
Conditions:
3750X#Show environment stack
<snip>
Temperature Value: 25 Degree Celsius
Temperature State: GREEN
Yellow Threshold : 46 Degree Celsius         <<<<<<<<<<<<<<<<<<<<<<<<<<<< 
Red Threshold    : 60 Degree Celsius

SNMP walk on Temperature status MIB and Sensor 2 - reaches its set threshold value